For the Installer
FIGHTER 360P
List of components
Connection Setting out
dimensions
A B C
70 Supply line, radiator circuit .............................................. Compression ring Ø 22 mm 100 . 465 ..... 90
71 Return line, radiator circuit .............................................. Compression ring Ø 22 mm 130 .. 465 ..... 190
73 Cold water connection ..................................................... Compression ring Ø 22 mm 260 .. 465 ..... 290
74 Hot water outlet from water heater .................................. Compression ring Ø 22 mm 290 .. 465 ..... 345
78 Filter cover
79 Drain and overflow water connection, water heater ......... R 15 male (with compression ring not removed)
80 Drain connection, heating system ................................... R 15 male
83 Temperature sensor, hot water
84 Ventilation opening
85 Expansion vessel
86 Temperature sensor, evaporator
87 Temperature sensor, extract air (concealed)
88 Temperature sensor, immersion heater operation
89 Temperature sensor, supply line
90 Ventilation connection exhaust air ................................... Ø 125 mm ................... 2095 ...... 295 ..... 160
91 Ventilation connection extract air ..................................... Ø 125 mm ................... 2095 ...... 295 ..... 485
92 Temperature sensor, exhaust air (hidden)
93 Temperature sensor, return
94 Temperature sensor, compressor operation
95 Overflow pipe, safety valve water heater
96 Overflow pipe, safety valve heating
97 Condensation water outlet, fan box
98 Overflow water discharge ................................................ PVC-pipe Ø 32 mm (outside diameter)
99 Collection funnel, waste water
100 Knob, setting Fuse
101 Knob, setting Max electrical output
102 No function
103 Type plate
1 Immersion heater 9 kW
2 Load monitor card
3 Operating thermostat, backup heating
6 Temperature limiter
7 Miniature circuit-breaker
8 Switch, position 1 - 0 -
9 Terminal block, power supply
10 Contactor, step 3, 6 kW
11 Terminal block, docking
12 Terminal block, docking
13 Terminal block, capacitor
14 Terminal block
15 Outside sensor
16 Circulation pump
17 Air screw, circulation pump
18 Pushbutton, Extra hot water
19 Shunt motor with handwheel
20 Connector, fan
22 Terminal block for fan speed
24 Immersion heater 4.5 kW
25 Push button, Operating mode
26 Motor protection, compressor
27 Compressor
28 Operating capacitor, compressor
29 Relay card with power supply unit
30 Push button, Fan speed
32 Display unit
33 High pressure pressostat
34 Central unit
35 Capacity setting, circulation pump
36 Fan, exhaust air
38 Knob, Offset heating curve
41 Low pressure pressostat
42 Pressure gauge, boiler
43 Shunt valve
44 Shutoff valve, pump and supply radiator circuit
46 Filler valve, water heater
47 Safety valve, water heater
48 Expansion valve
49 Combined filling and non-return valve, heating
system
50 Shutoff valve, return line radiator circuit
51 Drain valve, heating system
52 Safety valve, heating system
53 Vacuum valve (hidden)
54 Fan transformer
57 Starter capacitor, exhaust air fan
61 Docking connection, requires special pipe from
NIBE
62 Evaporator
63 Air filter (Filter type G2)
65 Drying filter with tank
66 Rating plate
67 Contactor, step 1, 3 kW
68 Compressor heater
69 Contactor, step 2, 4,5 kW
49