Control
FIGHTER 360P
For the Installer
38
8.0 Other settings
Menu 8.4.0 Fan settings
Settings and readings regarding fan speed are made
on the sub-menus to this menu.
Fan settings
8.4.0
Menu 8.5.4 Return
Return to Menu 8.5.0.
Return
8.5.4
Menu 8.6 Return
Return to Menu 8.0.
Return
8.6
Menu 8.4.3 Return
Return to Menu 8.4.0.
Return
8.4.3
Menu 8.5.0 Night coolness
Pressing the enter button takes you to sub-menus
where readings and settings concerning night cool-
ness are made. When the temperature in the house is
high and the outdoor air temperature is lower, a cool-
ing effect can be obtained by forcing the fan speed.
Night coolness
8.5.0
U
N
U
Menu 8.5.1 Night coolness
The night coolness is set On or Off here.
Off
Night coolness
8.5.1
U
Menu 8.5.2 Start temp. coolness
At what temperature on the exhaust air sensor (92)
should night cooling start.
25°C
Start temp. coolness
8.5.2
U
Menu 8.5.3 Min. diff. coolness
The minimum difference between the exhaust air tem-
perature and the outdoor air temperature for night
cooling to be activated is chosen here.
6°C
Min. diff. coolness
8.5.3
U
N
N
Menu 8.4.1 Return-time speed II
Here you select the time that should apply for fan
speed II when activated using the Fan speed button,
i.e. when the return to normal fan speed should take
place. The value can be set from 1 to 10 hours.
4 h
Return-time speed II
8.4.1
U
Menu 8.4.2 Return-time speed I
Here you select the time that should apply for fan
speed I when activated using the Fan speed button,
i.e. when the return to normal fan speed should take
place. The value can be set within the ranges 1 to 10
hours or 1 to 16 days.
4 h
Return-time speed I
8.4.2
U