English – 9
6.1 - Connecting a radio receiver
Thecontrolunithasaconnectorforttinga4channelradiocardcompletewith
SMslot.Thisremotecontroldevicefunctionsbymeansoftransmitterswhich
act on the inputs as per the following table:
Output Receiver Control unit input
N°1 Stepbystep
N°2 AUX(resetvalue:PartiallyOpen1)
N°3 “Openonly”
N° 4 “Close only”
6.2 - Connecting model PS124 buffer battery
PS124bufferbatteriescanbeusedtosupplythecontrolunitincaseofnetwork
blackouts.Toinstallandconnectthebattery,proceedasshowning. 10.
6.3 - Connecting the Solemyo system
Thecontrolunitisdesignedtobepoweredwiththe“Solemyo”photovoltaic
system(photovoltaicpaneland24Vbattery).ToconnecttheSolemyobattery
to the control unit, use the socket on the control unit that is normally used for
thebufferbattery(seeparagraph6.2).
IMPORTANT!
- When the automation is powered by the “Solemyo” system, it MUST
NOT BE POWERED at the same time from the electrical mains.
- The Solemyo system can be used only if the “Everything in stand by”
function on the con trol unit is ON and the connections are as shown in
the diagram in g. 5a.
FURTHER DETAILS: accessories
6
No LEDs are on:
Check whether the control unit is powered (measure a voltage of about
30Vdcatterminals9-10(or24Vdcwithbatterypower).
•Checkthe2fuses,ifnoteventheP1Ledisonorashingaseriousfaulthas
probably occurred and the control unit must therefore be replaced.
The P1 LED ashes regularly but the input LED’s L1, L2...L5 do not
reect the state of the respective inputs
Switch the unit off for the moment in order to exit a possible programming
phase.
• Carefullychecktheconnectionsonterminals11to16.
LED P1 ashes every 4 seconds
• Thecontrolunitisin“Everythinginstandby”status.
The “Automatic search” procedure does not start up
• The“Automaticsearch”procedureonlystartsifithasneverbeenperformed
beforeorifthememoryhasbeendeleted.Tocheckwhetherthememoryis
emptyswitchofftheunitforamoment.Whenitisswitchedonagain,allthe
Ledsshouldashrapidlyforabout6seconds.Iftheyonlyashfor3sec-
onds, the memory already contains valid values. If a new “Automatic search”
is required, the memory must be completely deleted.
The “Automatic search” procedure has never been performed but it
either does not start or it behaves incorrectly
• Thesystemandallthesafetydevicesmustbeoperativeinordertoactivate
the “Automatic search” procedure.
Make sure that no device connected to the inputs cuts in during the “Auto-
matic search” procedure.
In order for the “Automatic search” procedure to start correctly, the input
Leds must be on as shown in g. 11,theP1Ledmustashonceasecond.
The “Automatic search” procedure was performed correctly but the
manoeuvre does not start
• Checkthatthesafetydevice(STOP,PHOTO,PHOTO1and,ifinstalled,
PHOTO2)LedsareonandthattherelativecommandLed(STEP-BY-STEP
orAUX)remainsonfortheentiredurationofthecommand.
If the “Phototest” function is activated but the photocells do not function cor-
rectly,theDIAGNOSTICSLEDindicatesthefaultbyashingfourtimes.
The gate inverts the direction while moving
An inversion is caused by:
• Thephotocellstriggering(PHOTO2duringtheopeningmanoeuvre,PHOTO
orPHOTO1duringtheclosingmanoeuvre).Inthiscase,checkthephotocell
connections and input LEDs.
• Thecurrentsensitivitydevicetriggerswhilethemotorsaremoving(notnear
themechanicalstops,therefore).Thisisconsideredasanobstacleand
TROUBLESHOOTING
(troubleshooting guide)
7
causesaninversion.Tondoutifthecurrentsensitivitydevicehastriggered,
counthowmanytimestheDiagnosticsLEDashes:1ashindicatesthatthe
currentsensitivitydevicetriggeredonaccountofmotor1,2ashesindicate
that this was caused by motor 2.
PRODUCT MAINTENANCE
8
As the MC424 control unit is electronic it requires no particular maintenance.
However,atleasteverysixmonthstheefciencyoftheentiresystemmustbe
checked according to the information described in chapter 3.
DISPOSAL OF THE PRODUCT
This product is an integral part of the automation, and therefore, they
must be disposed of together.
As for the installation operations, at the end of the life of this product, the dis-
mantlingoperationsmustbeperformedbyqualiedpersonnel.
Thisproductismadefromdifferenttypesofmaterials:somecanberecycled,
others must be disposed of. Please inform yourselves on the recycling or dis-
posal systems provided for by the laws in force in your area, for this category
of product.
CAUTION! – some parts of the product can contain polluting or dangerous
substances which, if dispersed in the environment, may cause serious harm to
the environment and human health.
As indicated by the symbol at the side, it is forbidden to
throwthisproductintodomesticrefuse.Therefore,follow
the “separated collection” instructions for disposal, accord-
ing to the methods provided for by local regulations in force,
or redeliver the product to the retailer at the moment of pur-
chase of a new, equivalent product.
CAUTION! – the regulations in force at local level may envisage heavy sanc-
tions in case of abusive disposal of this product.
EN
www.metalines.com
sales@metalines.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice MOONCLEVER MC424 and is the answer not in the manual?

Nice MOONCLEVER MC424 Specifications

General IconGeneral
BrandNice
ModelMOONCLEVER MC424
CategoryControl Unit
LanguageEnglish

Related product manuals