3HE 17358 AAAB TQZZA
source-port 1/1/10 --------------------
> Not Required if port is already configured, but in admin down state
shutdown
exit
ref2
source-port 1/1/11 --------------------
> Not Required if port is already configured, but in admin down state
shutdown
exit
config> system> sync-if-timing> commit
config> system> sync-if-timing> begin
ptp
no shutdown
exit
ref-order ptp [Must be configured]
config> system> sync-if-timing> commit
After the preceding commands are run, the frequency and time are
provided by PTP [configure>system>ptp>no shutdown] only. This is a
standalone PTP mode.
6.5.13 Configuration Example to Use PTP and SyncE
References on 7210 SAS-Mxp, 7210 SAS-R6,
7210 SAS-R12, 7210 SAS-Sx 1/10GE, and
7210 SAS-T
The 7210 SAS-Mxp, 7210 SAS-R6, 7210 SAS-R12, 7210 SAS-Sx 1/10GE, and
7210 SAS-T support the configuration of PTP and SyncE references at the same
time. On these platforms, ref-order can be set to config>system>sync-if-
timing>ref-order ref1 ref2 ptp.
The following configuration example shows the use of PTP and syncE references
simultaneously:
*A:SAS-T-B>config>system>sync-if-timing# info detail
----------------------------------------------
ql-selection
ref-order ptp ref1 ref2 --
> All three reference can be configured simultaneously
ref1
source-port 1/1/1
no shutdown
no ql-override
exit