System Management
410
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
© 2021 Nokia.
Use subject to Terms available at: www.nokia.com
3HE 17358 AAAB TQZZA
Parameters card-type — Specifies an identifier used to match the configured slot module with the
equipped slot module. Table 42 and Table 43 provides the list of acronyms that can
be used to identify the supported modules usable with the clip-on device.
Values SFC1A, SFC1B, SFC1C, SFC1D, SFC1E, SFC1F, SFC1G, SFC1H,
SFC2A&B, SFC2C&D, SFC2E&F, SFC2G&H, SFC4A-D, SFC4E-H,
SFC8 (CWDM)
ANY, EALPFG SFD8A_R, SFD8B_R, SFD8C_R, SFD8D_R,
SFD4A_R, SFD4B_R, SFD4C_R, SFD4D_R, SFD4E_R,
SFD4F_R, SFD4G_R, SFD4H_R, SFD2A_R, SFD2B_R,
SFD2C_R, SFD2D_R, SFD2E_R, SFD2F_R, SFD2G_R,
SFD2H_R,SFD2I_R, SFD2L_R, SFD2M_R, SFD2N_R, SFD2O_R,
SFD2P_R, SFD2Q_R, SFD2R_R, SFD8A, SFD8B, SFD8C,
SFD8D, SFD4A, SFD4B, SFD4C, SFD4D, SFD4E, SFD4F, SFD4G,
SFD4H, SFD2A, SFD2B, SFD2C, SFD2D, SFD2E, SFD2F, SFD2G,
SFD2H, SFD2I, SFD2L, SFD2M, SFD2N, SFD2O, SFD2P, SFD2Q,
SFD2R (DWDM)
ascii-string — Can use ASCII alphabets or numbers. Valid card-type
acronyms are listed in the Table 43.
shutdown
Syntax [no] shutdown
Context config>system>vwm-shelf>card
Platforms 7210 SAS-M (network and access-uplink), 7210 SAS-T (network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description This command allows the user to administratively disable the management of a specific
module inserted in a slot on the clip-on device. When this command is executed, the
7210 SAS software clears all pending events/traps/alarms/LED related to this card.
The no form of this command allows the user to administratively enable the management of
the card on the clip-on device. The software raises appropriate events/traps/alarms for the
card.
Default no shutdown
6.12.2.1.3 Virtual Chassis (VC) Configuration Commands
vc-stack
Syntax vc-stack
Context config>system