System Management
428
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
© 2021 Nokia.
Use subject to Terms available at: www.nokia.com
3HE 17358 AAAB TQZZA
Default freq-source ptp
Parameters freq-source — Specifies whether PTP is used for frequency and time recovery or only for
time recovery. If ptp is specified, PTP is used for both frequency and time recovery.
If ssu is specified, PTP is used only for time recovery.
Values ptp, ssu
clock-type
Syntax clock-type boundary
clock-type ordinary slave
Context config>system>ptp
Platforms 7210 SAS-M (network and access-uplink), 7210 SAS-Mxp, 7210 SAS-R6, 7210 SAS-R12,
7210 SAS-Sx 1/10GE (standalone), and 7210 SAS-T (network and access-uplink)
Description This command configures the type of clock. The clock-type can only be changed when PTP
is shutdown.
When changing the clock-type to or from a boundary clock on the 7210 SAS-R6,
7210 SAS-R12, 7210 SAS-Mxp, and 7210 SAS-T platforms, the node must be rebooted for
the change to take effect. Ensure that measures are taken to minimize service disruption
during the reboot process.
Default ordinary slave
Parameters boundary — Keyword to configure the clock as a boundary clock capable of functioning
as both a master and slave concurrently.
ordinary slave — Keyword to configure the clock as an ordinary PTP slave.
domain
Syntax domain domain
no domain
Context config>system>ptp
Platforms 7210 SAS-M (network and access-uplink), 7210 SAS-Mxp, 7210 SAS-R6, 7210 SAS-R12,
7210 SAS-Sx 1/10GE (standalone), and 7210 SAS-T (network and access-uplink)
Description This command configures the PTP domain.
The domain cannot be changed unless PTP is shut down.
If the PTP profile is changed, the domain is changed to the default domain for the new PTP
profile.