436
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
© 2021 Nokia.
Use subject to Terms available at: www.nokia.com
3HE 17358 AAAB TQZZA
Parameters g8265dot1-2010 — Keyword to conform to the ITU-T G.8265.1 specification.
ieee1588-2008 — Keyword to conform to the 2008 version of the IEEE 1588 standard.
g8275dot1-2014 — Keyword to conform to the ITU-T G.8275.1 specification.
6.12.2.1.6 Date and Time Commands
set-time
Syntax set-time [date] [time]
Context admin
Platforms Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode
Description This command sets the local system time.
The time entered should be accurate for the time zone configured for the system. The system
will convert the local time to UTC before saving to the system clock which is always set to
UTC. This command does not take into account any daylight saving offset if defined.
Parameters date — Specifies the local date and time accurate to the minute in the YYYY/MM/DD
format.
Values YYYY is the four-digit year
MM is the two-digit month
DD is the two-digit date
time — Specifies the time (accurate to the second) in the hh:mm[:ss] format. If no
seconds value is entered, the seconds are set to 00.
Values hh is the two-digit hour in 24 hour format (00=midnight, 12=noon)
mm is the two-digit minute
Default 0
time
Syntax time
Context config>system
Platforms Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode