7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
System Management
3HE 17358 AAAB TQZZA © 2021 Nokia.
Use subject to Terms available at: www.nokia.com
485
If multiple alarm-contact input pins share an alarm-contact output, the system generates the
alarm-contact output even if any one of the alarm-contact input is triggered and the system
clears alarm-contact output only when all the alarm-contact input pins are cleared.
The severity parameter configured by the user determines the appropriate alarm-contact
output to be used for generation and clearing the alarm.
Default major
Parameters critical — Specifies that a critical alarm output is generated or cleared.
major — Specifies that a major alarm output is generated or cleared.
minor — Specifies that a minor alarm output is generated or cleared. This parameter is
only supported on 7210 SAS-T and 7210 SAS-Mxp.
none — Specifies that no alarm output is generated or cleared.
clear-alarm-msg
Syntax [no] clear-alarm-msg {alarm-msg-text}
Context config>system>alarm-contact-input
Platforms 7210 SAS-M (network and access-uplink), 7210 SAS-T network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description This command allows the user to configure a text message for use along with SNMP trap and
Log message that are sent when the system clears an alarm. The system generates a default
message if the message is not configured.
The no form of this command removes the configured alarm clear message.
Parameters alarm-msg-text — Specifies a printable character string, up to 160 characters.
description
Syntax description description-string
Context config>system>alarm-contact-input
Platforms 7210 SAS-M (network and access-uplink), 7210 SAS-T (network and access-uplink),
7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Note: The system relays the alarm-contact input to the appropriate alarm-contact output
only if the alarm-contact output is available on the platform.