7 Technical data
BU 0250 en-3021 179
Frequency inverter
type
SK 2xxE-FDS-…
-221-340- -301-340- -401-340- -551-340- -751-340-
1 1 2 2 2
Nominal motor power
(4-pole standard motor)
400 V
3.0 kW 4.0 kW 5.5 kW 7.5 kW
3 AC 380 … 500 V, - 20 % / + 10 %, 47 … 63 Hz
Input current
rms
1)
7.0 A 8.9 A 11.7 A 15.0 A
FLA
2)
6.3 A 8.0 A 10.6 A 13.7 A
Output current
FLA
2)
6.7 A
3)
8.5 A
3)
11.0 A
3)
14.2 A
3)
Min. brake resistance Accessories
200 Ω 110 Ω 110 Ω 68 Ω 68 Ω
Max. continuous power / max. continuous current:
General fuses (AC) (recommended)
UL fuses (AC) – permitted
6)
X
X
1) Note derating curve ( Section 8.4.4 "Reduced output current due to low voltage").
2) FLA – Full Load Current, maximum current for the entire mains voltage range as stated above (380 V – 500 V) according to UL/CSA
3) Only with "Fan" (standard equipment)
4) for group fuses: maximum fuse size: 30 A
5) Maximum mains short-circuit current, Note: Further restrictions are possible depending on the plug connector which is used (
Section 1.6.1
"UL and CSA approval")
6) "inverse time trip type" according to UL 489