7 Technical data
BU 0250 en-3021 179
Frequency inverter
type
SK 2xxE-FDS-
-221-340- -301-340- -401-340- -551-340- -751-340-
Size
1 1 2 2 2
Nominal motor power
(4-pole standard motor)
400 V
2.2 kW
3.0 kW 4.0 kW 5.5 kW 7.5 kW
480 V
3 hp
4 hp
5 hp
7 ½ hp
10 hp
Mains voltage
400 V
3 AC 380 … 500 V, - 20 % / + 10 %, 47 … 63 Hz
Input current
rms
1)
4.9 A
7.0 A 8.9 A 11.7 A 15.0 A
FLA
2)
4.4 A
6.3 A 8.0 A 10.6 A 13.7 A
Output voltage
400 V
3 AC 0 … Mains voltage
Output current
rms
1)
5.5 A
7.5 A
9.5 A
12.5 A
16.0 A
FLA
2)
4.9 A
3)
6.7 A
3)
8.5 A
3)
11.0 A
3)
14.2 A
3)
Min. brake resistance Accessories
200 110 110 68 68
Max. continuous power / max. continuous current:
S1-40°C
2.2kW / 5.5A
3.0kW / 7.5A
4.0kW / 9.5A
5.5kW / 12.5A
7.5kW / 16.0A
General fuses (AC) (recommended)
slow-blowing
10 A
4)
16 A
4)
16 A
4)
20 A
4)
25 A
4)
Isc
5)
[A]
UL fuses (AC) permitted
Class
20 000
65 000
Fuse
CC, J, R, T, G, RK1, RK5
X
30 A
30 A
30 A
30 A
30 A
CB
6)
480 V
X
30 A
30 A
30 A
30 A
30 A
500 V
X
30 A
30 A
30 A
30 A
30 A
1) Note derating curve ( Section 8.4.4 "Reduced output current due to low voltage").
2) FLA Full Load Current, maximum current for the entire mains voltage range as stated above (380 V 500 V) according to UL/CSA
3) Only with "Fan" (standard equipment)
4) for group fuses: maximum fuse size: 30 A
5) Maximum mains short-circuit current, Note: Further restrictions are possible depending on the plug connector which is used (
Section 1.6.1
"UL and CSA approval")
6) "inverse time trip type" according to UL 489