32 BU 0250 en-3021
Pos: 71 /Anleitungen/ Elektronik/FU und St arter/2. Montage und Inst allation/Monta ge/FDS [SK xxxE-FDS]/A usstattungsvarian ten_04_Konfigurati on der Optionsplätze der Ansteuerungsebene_ 01 [SK 2xxE-FDS] @ 50\mod_1600850 259050_388.doc x @ 2672117 @ 4 @ 1
2.2.2.2 Configuration of option slots of the control level
The option slots M1 to M8 are designed for M12 plug connectors. The device-relevant assignment of
the connections or functions of the individual option slots is directly printed on the option slot.
Option slot Option type Function Relevant
parameter
Comment
M1
a
No option
b
Initiator 1 / 4
DIN1
P420[-01]
Not available if M5 c has
zero track. Set the
function of the zero track
in P420[-01].
DIN4
P420[-04]
M2
a
No option
b
Initiator 4
DIN4
P420[-04]
M3
a
No option
b
Actuator 1 / 2
DOUT1
P434[-01]
DOUT2
P434[-02]
M4
a
No option
b
Actuator 2
DOUT2
P434[-02]
M5
a
No option
b
Initiator 2 / 3
DIN2
P420[-02]
DIN3
P420[-03]
c
HTL encoder
1)
HTL-A
P420[-02]
HTL-B
P420[-03]
d
System bus Master
SYSM
M6
a
No option
b
Initiator 3
DIN3
P420[-03]
only SK 250E-FDS /
SK 270E-FDS
c
Safe stop
STO
only SK 260E-FDS /
SK 280E-FDS
M7
a
No option
b
Initiator 6 / 7
AIN1 /
DIN6
P400[-01] /
P420[-06], P113
H1 / H2 only usable to a
limited extent
AIN2 /
DIN7
P400[-02] /
P420[-07], P113
c
System bus Slave or absolute
encoder
SYSS
M8
a
No option
b
Initiator 7
AIN2 /
DIN7
P400[-02] /
P420[-07], P113
only SK 250E-FDS /
SK 260E-FDS,
H1 / H2 only usable to a
limited extent
c
24 V DC supply
2)
24VI
d
AS-Interface (“AUX“)
AUX
only SK 270E-FDS /
SK 280E-FDS
e
AS-Interface
(“AS-i”)
ASI
f
AS-Interface (“AXS“)
AXS
g
AS-Interface (“ASS“)
ASS
1)
Encoder cable available on request If the encoder has a zero track, evaluation of the zero track is only via DIN1.
2)
The 24 V DC control voltage can also be supplied via M8 c (AUX), M8 f (AXS) or the option slots X1 or Z1 Z4 of the