5 Parameter
BU 0250 en-3021 131
Pos: 408 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ P5xx Zusatzparamet er @ 0\mod_1328091531180_388. docx @ 10880 @ 3 @ 1
5.2.6 Additional parameters
Parameter
{factory setting}
Setting value / Description / Note Supervisor Parameter set
Pos: 409 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P500- P599/Parameter P501 Umri chtername @ 0\mod_132809164 5446_388.docx @ 10904 @ @ 1
P501 [-01]
...
[-20]
Inverter name
(Inverter name)
A…Z
(char)
{ 0 }
Free input of a designation (name) for the device (max. 20 characters). With this, the frequency
inverter can be uniquely identified for setting with NORD CON software or within a network.
Pos: 410 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P500- P599/Parameter P502 W ert Leitfunktion [SK 2xxE- FDS] @ 12\mod_1467288632007_3 88.docx @ 335305 @ @ 1
P502 [-01]
...
[-03]
Master function value
(Master function value)
S P
0 ... 57
{ all 0 }
Selection of up to 3 master values of a master for output to a bus system (see P503). The
assignment of these master values to the slave is carried out via (P546). Definition of frequencies:
( Section 8.9 "Definition of setpoint and actual value processing (frequencies)")
[-01] = Master value 1 [-02] = Master value 2 [-03] = Master value 3
Selection of possible setting values for master values:
0 =
Off
17 =
Value analog input 1
1 =
Actual frequency
18 =
Value analog input 2
2 =
Actual speed
19 =
Setpoint freq. Master value, "Setpoint
frequency master value"
3 =
Current
20 =
Setpoint freq. after ramp master value,
"Setpoint frequency from ramp master
value“
4 =
Torque current
21 =
Actual freq. without slip Master value
"Actual frequency without master value
slip"
5 =
Digital IO status
22 =
Speed encoder
6 =
... 7 reserved, Posicon BU0210
23 =
Actual frequency with slip,
"Actual frequency with slip"
8 =
Setpoint frequency
24 =
Master value Actual freq. w. slip
"Master value, actual freq. with slip"
9 =
Error number
53 =
Actual value 1 PLC
10 =
... 11 reserved, Posicon BU0210
54 =
Actual value 2 PLC
12 =
Bus IO Out Bits 0-7
55 =
Actual value 3 PLC
13 =
... 16 reserved, Posicon BU0210
56 =
Actual value 4 PLC
57 =
Actual value 5 PLC
NOTE: Details with regard to target and actual value processing: ( Section 8.8).