2 Assembly and installation
BU 0250 en-3021 27
2 Assembly and installation
Pos: 56 /Anleitungen/ Elektronik/FU und St arter/2. Montage und Inst allation/Montage/ FDS [SK xxxE-FDS]/Monta ge und Installation_a llgemeine Infos [ SK xxxE-FDS] @ 48\mod_159714086346 6_388.docx @ 2660784 @ @ 1
No options can be retrofitted. All options must be recorded by NORD when ordering and before the
production process. The customer must not open the device at any time and does not need to. The
device is mounted by using mounting lugs that are freely accessible from the outside. The electrical
connection of mains, motor and signal cables is only possible via respective plug connectors. The
optionally available control elements (e.g. switches) are mounted in a freely accessible position.
Opening a defined blind plug is only required for the temporary connection of a diagnostic tool. The
diagnostic tools comprise:
• Parameterisation unit SK CSX-3H/ SK PAR-3H
• NORDAC ACCESS BT with the NORDCON APP
• PC with the NORDCON software
Pos: 57 /Anleitungen/ Elektronik/FU und St arter/2. Montage und Inst allation/Monta ge/FDS [SK xxxE-FDS]/Monta ge_01 [SK xxxE-FDS] @ 48\mod_159 7146467682_388.doc x @ 2660830 @ 2 @ 1
2.1 Installation
The devices are designed for an installation close to the motor and do not need a control cabinet due
to their protection class.
Distance from device:
The devices require sufficient ventilation for protection against overheating
and must therefore not be covered.
Mounting can be immediately next to each other.
The required distances for the connectio
maintained.
Installation position: • Vertical, i.e. bottom position of cable connection (power connection)
• Horizontal, i.e. top position of control elements and diagnostic LEDs
See also the following illustration.
Pos: 58 /Anleitungen/ Elektronik/FU und St arter/2. Montage und Inst allation/Montage/ FDS [SK xxxE-FDS]/Monta ge_02 [SK 2xxE-FDS] @ 38\mod_156 8103028072_388.doc x @ 2558207 @ @ 1
Dimensions:
The frequency inverters are supplied in various sizes depending on their output. Depending on the
power and special equipment, the heat sink may be equipped with a fan. In general, size 0 is not
available with a fan.
Power [kW]
Frequency inverter type
SK 2xxE-FDS-…
Size
Housing dimensions Wall mounting
3)
by to by to B H L
2)
L1 L2 X1 X2 X3
∅
243
312 294 243 110 193 263 5.5
All dimensions in [mm]
2)
Without maintenance switch 307 mm
Depending on configuration