4 Commissioning
BU 0250 en-3021 63
Pos: 164 /Anleitungen/ Elektronik/F U und Starter/4. Inbetriebna hme/SK 1xxE, SK 2xxE, - FDS/Werkseinstellunge n/Werkseinste llungen [SK 1xxE, SK 2xxE, FDS] @ 1\mod_1343 217972184_388.doc x @ 37256 @ 2 @ 1
4.2 Factory settings
Pos: 165 /Anleitungen/ Elektronik/F U und Starter/4. Inbetriebna hme/SK 1xxE, SK 2xxE, - FDS/Werkseinstellunge n/Werkseinste llungen_01 [SK 1x0E, SK 2 xxE, SK 2xxE-FDS] @ 8\mod_1441286953067_ 388.docx @ 239676 @ @ 1
All frequency inverters supplied by Getriebebau NORD are pre-programmed with the default setting
for standard applications with 4 pole standard motors (same voltage and power). For use with motors
with other powers or number of poles, the data from the rating plate of the motor must be input into the
parameters P201...P207 under the menu item >Motor data<.
All motor data (IE1, IE4) can be pre-set using parameter P200. After use of this function, this
parameter is reset to 0 = no change! The data is loaded automatically into parameters P201...P209
and can be compared again with the data on the motor rating plate.
3~ Mot
IEC 56
IM B3
cos 0,74
cosj 0,74
IP55
Rot. KL 16
Th.Cl.F
EN60034
60 Hz
460 V Y
5,2 A
2,5 kW
1765 /min
1440 /min
P206
P201
P204
P203
P202
P200
9,0 / 5,2 A
50 Hz
2,2 kW
P207
P200 Motor list:
0 = no change 8 = 0.37kW 400V
1 = no motor 9 = 0.50PS 460V
2 = 0.25kW 230V 10 = 0.55kW 230V
3 = 0.33PS 230V 11 = 0.75PS 230V
4 = 0.25kW 400V 12 = 0.55kW 400V
5 = 0.33PS 460V 13 = 0.75PS 460V
6 = 0.37kW 230V 14 = 0.75kW 230V
7 = 0.50PS 230V ....
230 / 400 V D/Y
For the correct operation of the drive unit, it is necessary to input the motor data (rating plate) as
precisely as possible. In particular, an automatic stator resistance measurement using parameter
P220 is recommended.
Pos: 166 /Anleitungen/ Elektronik/F U und Starter/4. Inbetriebna hme/SK 1xxE, SK 2xxE, - FDS/Werkseinstellunge n/Werkseinste llungen_02_IE2_3 @ 30\mod _1552397134005_388.doc x @ 2506317 @ @ 1
Motor data for IE2 / IE3 motors are provided via the NORDCON software. With the aid of the "Import
motor parameter" function (also refer to the manual for the NORDCON software BU 0000), the
required data set can be selected and imported into the frequency inverter.