8 Additional information
BU 0250 en-3021 199
Installed plug connector type:
HARTING Q8/0+ (socket)
Recommended products for mating connectors to the installed plug connector system
Hybrid plug connector HAN Q8/0 (pin)
Number Designation Manufacturer Information
1 x
Sleeve housing, HAN-Compact
Harting
Straight cable outlet, M25
(19 12 008 0429 )
1 x
Contact insert HAN Q8/0 (pin insert)
Harting
(09 12 008 3001)
4 x
Crimp contact socket 1.5 mm²
Harting
(09 33 000 6104)
1 x
HAN-Compact Half cable gland
Harting
M25 14…17mm
(19 12 000 5158)
Pos: 683 /Anleitungen/ Elektronik/F U und Starter/8. Zusatzinf ormationen/Zubehör /M12 Y-Verteiler [ SK 2xxE-FDS] @ 21\mod_1519221067 544_388.docx @ 2406944 @ 3 @ 1
8.10.2 M12 Y distributor
To create complex supply or communication lines we recommend the use of Y distributors. These are
mounted directly on the relevant M12 plug connector of the filed distributor and enable direct
connection to the particular line.
Designation Material number connection Option slot Contact diagram
SK TIE4-M12-SYSS-YMF
275274523
System bus
M7
SK TIE4-M12-INI-YFF
275274525
Initiator
M1, M3, M5,
M7
SK TIE4-M12-POW-YMF
275274526
24 V DC
M8
SK TIE4-M12-STO-YMF
275274527
STO
M6
Connection
Meaning
(a) Inverter side
(b), (c)
Supply cable (as input or output)