8 Additional information
BU 0250 en-3021 187
EMC overview of standards that are used in accordance with EN 61800-3
as checking and measuring procedures:
Cable-related emission
(interference voltage)
EN 55011
Radiated emission
(interference field strength)
EN 55011
immunity EN 61000-6-1, EN 61000-6-2
ESD, discharge of static electricity
EMF, high frequency electro-magnetic
fields
EN 61000-4-3 10 V/m; 80 – 1000 MHz
Burst on mains and motor cables
Surge (phase-phase / phase-ground)
Cable-led interference due to high
frequency fields
EN 61000-4-6 10 V, 0.15 – 80 MHz
Voltage fluctuations and drops
Voltage asymmetries and frequency
changes
EN 61000-2-4 3 %; 2 %
Table 7: Overview according to product standard EN 61800-3