8.3.3 EMC of device
Pos: 647 /Anleitungen/ Elektronik/F U und Starter/1. Allgemeine s/Sicherheits- und I nstallationshin weise und Warn- Gefahrenhin weise/neu/W arn- und Gefahrenhinwei se/ACHTUNG - EMV – Störung der Umgebun g [SK xxxE-FDS] @ 42\mod_1590 583661894_388.doc x @ 2628520 @ @ 1
EMC interference to the environment
This device produces high-frequency interference, which may make additional suppression measures
necessary in domestic environments (see 8.3.2 "EMC evaluation").
The use of shielded motor cables is essential in order to maintain the specified radio interference
suppression level.
Pos: 648 /Anleitungen/ Elektronik/F U und Starter/8. Zusatzinformation en/EMV/_EMV des Gerätes_02 [SK 1xxE, SK 2xxE, SK 5xxE/P, SK xxxE-FDS] @ 19\mod_15118753908 78_388.docx @ 2374113 @ @ 1
The device is exclusively intended for commercial use. It is therefore not subject to the requirements
of the standard EN 61000-3-2 for radiation of harmonics.
The limit value classes are only achieved if
• the wiring is EMC-compliant
• the length of shielded motor cable does not exceed the permissible limits
Pos: 649 /Anleitungen/ Elektronik/F U und Starter/8. Zusatzinf ormationen/EMV/_E MV des Gerätes_Tabelle Lei tungslängen [SK 2xxE- FDS] @ 12\mod_14673664005 01_388.docx @ 336004 @ @ 1
• The standard pulse frequency (P504) is used
The motor cable shield must be connected on both sides.
Device version
Max. motor cable length,
shielded
Conducted emissions
150 kHz - 30 MHz
Class C2 Class C1
Standard configuration for
operation on TN/TT networks
(active integrated mains filter)
10 m -
Pos: 650 /Anleitungen/ Elektronik/F U und Starter/8. Zusatzinf ormationen/EMV/_E MV des Gerätes_PE_Ansc hluß [SK 2xxE-FDS] @ 12\mod_146 8911189531_388.doc x @ 339906 @ @ 1
The PE contacts of the connection cables (e.g
mains and motor cable) are connected together in
the device. For fault-
reco
mmend a further connection between the PE
of the device and the PE of the plant construction.
Two screw terminals are available for this on the
heat sink.