NORDAC LINK (SK 250E-FDS ... SK 280E-FDS) – Users Manual for Frequency Inverters as Field Distributors
56 BU 0250 en-3021
Pos: 143 /Anleitungen/ Elektronik/F U und Starter/3. Anzeige, Bedi enung und Optionen/Bedi enung [SK 1xxE, 2xxE, - FDS]/Bedien- und Par ametrieroptionen [SK xxxE -FDS] @ 49\mod_1599038560 759_388.docx @ 2665927 @ 2 @ 1
3.2 Control and parametrisation options
There are different control options available, installed on the option slots H1 and H2. The required
control options and their functions must be selected upon ordering or during the configuration process
( 2.2.2.2 "Configuration of option slots of the control level"). Retrofitting is not possible.
Parameterisation units furthermore allow for an access to and the adjustment of the device’s
parametrisation.
Designation Material No. Comment
Control and parameterisation units
(handheld)
Bluetooth stick
Pos: 144 /Anleitungen/ Elektronik/F U und Starter/3. Anzeige, Bedi enung und Optionen/Bedi enung [SK 1xxE, 2xxE, - FDS]/Bedien- und Par ametrierboxen, Verwend ung_01 [SK 1x0E, SK 2xxE, SK xxxE-FDS] @ 48\mod_1597666648135 _388.docx @ 2663138 @ 35 @ 1
3.2.1 Control and parameterisation units, use
With an optional SimpleBox or ParameterBox all parameters can be conveniently accessed, read out
or adjusted. The changed parameter data are stored in the non-volatile EEPROM memory.
Up to five complete device data sets can be stored and accessed in the ParameterBox.
SimpleBox or ParameterBox can be connected to the device via an RJ12-RJ12 cable.
Figure 1: SimpleBox, handheld, SK CSX-3H Figure 2: ParameterBox, handheld, SK PAR-3H
Module Description Data
SK CSX-3H
(SimpleBox handheld)
Used for commissioning,
parameterisation, configuration and
control of the device
1)
.
• 4-digit 7-segment LED display, membrane
button
• IP20
• RJ12-RJ12 cable
(connection to the device
1)
)
SK PAR-3H
(ParameterBox handheld)
Used for commissioning,
parameterisation, configuration and
control of the device and its options
(SK xU4-…). Complete data sets can be
stored.
• 4-line LCD display, backlight, membrane
button
• Stores up to five complete parameter data
sets
• IP20
• RJ12-RJ12 cable (connection to the
device)
• USB cable (connection to PC)
Does not apply for option modules, e.g. bus interfaces
Connection
1. Remove the diagnostics glass of the RJ12 socket.