2 Assembly and installation
BU 0250 en-3021 49
Notes for DIN6 and DIN7:
Digital inputs DIN6 and DIN7 depend directly on analogue inputs AIN1 and AIN2. This means that the digital functions can only be used if the
analogue functions are disabled (corresponding to the factory setting).
Pos: 128.8 /Anleitung en/Elektronik/F U und Starter/2. Montag e und Installation/E lektrischer Anschlus s/SK 1xxE, SK 2xxE, SK 5xxP, SK xxxE-FDS/Steuertei l/Details Steueransc hlüsse (Sammlung)/ Details Steueransch lüsse_04_TF [SK xxxE-FDS] @ 49\mod_1599030230960_38 8.docx @ 2665668 @ @ 1
PTC resistor input
Monitoring of motor temperature using PTC
The motor´s PTC resistor (TF) is
connected via the Q8 motor connection.
Use a shielded cable.
Connect a temperature sensor to put the device into operation
mode. As an alternative, you can deactivate the input
function. In this case, however, the thermal monitoring of the
motor is no longer possible.
TF+
PTC resistor input +
P425 On
TF-
PTC resistor input -
Pos: 128.9 /Anleitung en/Elektronik/F U und Starter/2. Montage und I nstallation/Ele ktrischer Anschluss/SK 1 xxE, SK 2xxE, SK 5xxP, SK xxxE-FDS/Steuertei l/Details Steueransc hlüsse (Sammlung) /Details Steueransch lüsse_05_Quelle Steuer spannung [SK xxxE-FDS] @ 11\mod_146616608006 0_388.docx @ 330160 @ @ 1
Control voltage source
Control voltage from the inverter, e.g. as power supply for accessories
24 V DC ± 25 %, short circuit-proof
Maximum load
1)
VO / 24V
Voltage output
-
-
GND / 0V
Reference potential GND
-
-
1)
See "Total currents" information (
Section 2.3.3 "Electrical connection of the control unit")
Pos: 128.10 /Anleitun gen/Elektronik/F U und Starter/2. Montage und I nstallation/Ele ktrischer Anschlu ss/SK 1xxE, SK 2xxE, SK 5xxP, S K xxxE-FDS/Steuerteil/ Details Steueran schlüsse (Sammlung)/ Details Steueransc hlüsse_05_Quelle Steu erspannung [SK 300 WI T] @ 48\mod_1596704239849_38 8.docx @ 2658313 @ @ 1
Control voltage source
Control voltage from device e.g for supply of accessories
24 V DC ± 25%, short-circuit protected
VO/ 24V
Voltage output
GND/ 0V
Reference potential GND
Pos: 128.11 /Anleitun gen/Elektronik/F U und Starter/2. Montage und I nstallation/Elektrischer Anschluss/SK 1xxE, SK 2xxE, SK 5xxP, SK xxxE-FDS/S teuerteil/Detai ls Steueranschlüsse ( Sammlung)/Details St eueranschlüsse_06_S teuerspannung_Einga ng [SK xxxE-FDS] @ 11\mod_14 66166134678_388.d ocx @ 330195 @ @ 1
Control voltage
connection
Supply voltage for the FI
24 V DC ± 25 %
200 mA … 800 mA, depending on load of
inputs and outputs and use of options
With option (-HVS): Automatic changeover between the
external supply via the connection plug and internal mains
unity if the connected control voltage is insufficient.
24V
Voltage input
-
-
GND / 0V
Reference potential GND
-
-
Pos: 128.12 /Anleitun gen/Elektronik/F U und Starter/2. Montage und I nstallation/Ele ktrischer Anschlu ss/SK 1xxE, SK 2xxE, SK 5xxP, SK x xxE-FDS/ Steuerteil/De tails Steueranschlüs se (Sammlung)/Detai ls Steueranschlüsse_ 06_Steuerspannun g_Eingang [SK 300P WI T] @ 48\mod_1596702623190_388. docx @ 2658276 @ @ 1
Control voltage
connection
Supply voltage for the device
24 V DC ± 25%, min. 380 mA
24 V
Input voltage
GND/ 0V
Reference potential GND
Pos: 128.13 /Anleitun gen/Elektronik/F U und Starter/2. Montage und I nstallation/Ele ktrischer Anschlu ss/SK 1xxE, SK 2xxE, SK 5xxP, SK xx xE-FDS/Steuerteil/De tails Steueransc hlüsse (Sammlung)/Detai ls Steueranschlüsse_ 07_SYS [SK 2xxE-FDS] @ 11\mod_1466166209620_388. docx @ 330230 @ @ 1
System bus
NORD-specific bus system for communicating with other devices (e.g. intelligent
option modules or frequency inverters)
Up to four frequency inverters (SK 2xxE,
SK 1x0E, SK 2xxE-FDS) can be operated
on a single system bus.
Address = 32 / 34 / 36 / 38
SYS H
System bus+
P509/510
Control terminals / Auto
SYS L
System bus-
P514/515
250kBaud / Address 32
dec
Pos: 128.14 /Anleitun gen/Elektronik/F U und Starter/2. Montage und I nstallation/Ele ktrischer Anschlu ss/SK 1xxE, SK 2xxE, SK 5xxP, SK xxxE-FDS/Steuerteil/ Details Steueran schlüsse (Sammlung)/ Details Steueransc hlüsse_08_BR [SK xxxE-FDS ] @ 12\mod_1466166292642_3 88.docx @ 330265 @ @ 1
Brake actuation
Connection and actuation of an electromechanical brake. The FI generates an
output voltage for this, which depends on the mains voltage. The assignment of the
correct brake coil voltage must be taken into account in the selection.
Connected loads:
( Section 2.3.2.4)
Current: ≤ 500 mA
Permissible switching cycle time:
to 150 Nm ≤ 1/s
to 250 Nm ≤ 0.5/s
BR+
Brake control
P107/114
0 / 0
BR-
Brake control
Pos: 128.15 /Anlei tungen/Elektronik/ FU und Starter/2. Monta ge und Installation/ Elektrischer Anschlu ss/SK 1xxE, SK 2xxE, SK 5xxP, SK xxxE -FDS/Steuer teil/Details Steueran schlüsse (Sammlung) /Details Steueransc hlüsse_10_ASI [SK xxxE-FDS] @ 12\mod_1466166363189 _388.docx @ 330300 @ @ 1
AS Interface
Control of FI via the simple field bus level: Actuator/sensor interface
Electrical data:
See 4.5.2 "Features and technical data"
ASI+
ASI+
P480 …
-
ASI-
ASI-
P483
-
Pos: 128.16 /Anleitun gen/Elektronik/F U und Starter/2. Montage und I nstallation/Ele ktrischer Anschlu ss/SK 1xxE, SK 2xxE, SK 5xxP, SK xxxE-FDS/Steuerteil/ Details Steueran schlüsse (Sammlung)/ Details Steueransc hlüsse_11_SH [SK 2xxE-FDS ] @ 12\mod_1466166398884_3 88.docx @ 330335 @ @ 1