EasyManua.ls Logo

Nord Drivesystems NORDAC LINK SK250E-FDS - Page 54

Nord Drivesystems NORDAC LINK SK250E-FDS
212 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NORDAC LINK (SK 250E-FDS ... SK 280E-FDS) Users Manual for Frequency Inverters as Field Distributors
54 BU 0250 en-3021
LED
No. Colour Description Signal status Meaning
2
Dual
Red/green
CU4 status
Off
Module (SK CU4-…) not ready for
operation,
no control voltage
no SK CU4-… module installed
Note: If a type SK CU4-IOE module is installed, the
LED also remains off.
Green On
Cyclic process data traffic in operation
Details: P173, bit 1
Flashing
green
2 Hz
The module is initialised, there is no cyclic
process data traffic.
Details: P173, bit 0
Flashing red
Flash
(1 x 0.25 s every
2.5 s)
SK CU4-EIP, -ECT, -POL:
"Timeout external bus"
SK CU4-CAO:
"Timeout node guarding (watchdog
NMT master)"
SK CU4-PBR:
"Timeout node guarding (watchdog
PROFIBUS DP master)"
SK CU4-DEV:
"Timeout (DeviceNet monitoring or time
set in parameter P151")
SK CU4-PNT:
"PROFINET Timeout"
Details: for SK CU4-PNT: P173 bit 4-6, otherwise
P173, bit 2
Double flash
(2 x 0.25 s every
2.5 s)
SK CU4-EIP, -ECT, -POL, -CAO, -
PBR:
"Timeout according to P151”
SK CU4-CAO:
"Incorrect DIP switch setting“
SK CU4-PNT:
"Process data (CTW) timeout"
"Hardware error CAN"
"Hardware error IO"
Details: for SK CU4-PNT: P173 bit 4-6, otherwise
P173, bit 3
2 Hz
SK CU4-EIP, -ECT, -POL:
"ASIC not accessible“
SK CU4-CAO, -DEV:
„Warning“
SK CU4-PBR:
„Bus interface system error“
Details: P173, bit 4
Red On
SK CU4-EIP, -ECT, -POL:
"General configuration error
SK CU4-CAO, -DEV:
„Bus OFF“
Details: P173, bit 5

Table of Contents