NORDAC LINK (SK 250E-FDS ... SK 280E-FDS) – Users Manual for Frequency Inverters as Field Distributors
60 BU 0250 en-3021
1.
Disconnecting the frequency inverter from the low voltage and checking the absence of
voltage in the device
Removing the EEPROM
2. Remove the transparent screw cap.
3. Pull off the EEPROM
Continue with step 5 if the frequency inverter is to be operated
without a plug-in EEPROM.
EEPROM installation
4.
Position the EEPROM so that its coding pin can be inserted into
the circular recess in the PCB (see arrow).
Insert the EEPROM vertically (perceptible locking).
5.
Replace the transparent screw cap (with sealing ring)
(tightening torque: 2.5 Nm).
Pos: 155 /Anleitungen/ Elektronik/F U und Starter/3. Anzeige, Bedi enung und Optionen/Opti onen [SK 1xxE, SK 2xxE]/ Option Steckbares E EPROM_03_Funktionswei se [SK 2x0E-FDS] @ 50\mod_160086 8472857_388.doc x @ 2672345 @ 5 @ 1