5 Parameter
BU 0250 en-3021 79
Pos: 221 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Allgemein/Parameter _03 [SK 2xxE, SK 2xxE-FDS] @ 9\ mod_1447403754466_388. docx @ 263205 @ @ 1
The individual parameters are combined in functional groups. The first digit of the parameter number
indicates the assignment to a menu group:
Menu group No. Master function
Operating displays
(P0--)
Display of parameters and operational values
Basic parameters
(P1--)
Basic device settings, e.g. on/off switching behaviour
Motor data
(P2--)
Electrical settings for the motor (motor current or start voltage (start-off
voltage))
Speed control
(P3--)
Setting of current and speed controllers and settings for rotary encoders
(incremental encoders) and settings for the integrated PC.
Control terminals
(P4--)
Assignment of functions for the inputs and outputs
Additional
parameters
(P5--)
Mainly monitoring functions and other parameters
Positioning
(P6--)
Setting of the positioning function (details
BU0210)
Information
(P7--)
Display of operating values and status messages
Pos: 222 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Allgemein/INFOR MATION - Werkseinste llung P523 [SK 1x0E, SK 2xxE, SK 2xxE-FDS, SK 5xxP] @ 33\mod_1557211910 368_388.docx @ 2533662 @ @ 1
Factory setting P523
The factory settings of the entire parameter set can be loaded at any time using parameter P523. For
example, this can be useful during commissioning if it is not known which device parameters have
been previously changed and could have an unexpected influence on the operating behaviour of the
drive.
The restoration of the factory settings (P523) normally affects all parameters. This means that all
motor data must subsequently be checked or reconfigured. However, parameter P523 also provides a
facility for excluding the motor data or the parameters relating to bus communication when the factory
settings are restored.
It is advisable to back up the present settings of the frequency inverter beforehand.