EasyManua.ls Logo

Novatech Kronos 2 Series - Web Interface; Table 1: Clock States; Table 2: Satellite Visualization

Novatech Kronos 2 Series
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kronos Series 3
20
Clock State
Description
Bad time
The error estimate is greater than the second user-defined threshold value. The clock
will raise a level 2 error and stop generating time signals. The dot matrix display will
show a corresponding message. The default value for this threshold is 1s. See section
GNSS Settings (Online) or Out-of-bound Limits (Offline) for information about how to
change this to a different value. Normal operation, with time signal generation and
display, is resumed as soon as enough satellites are re-acquired and the error estimate
drops below the user-defined threshold.
Table 1: Clock states
3.4 Web Interface
The clock provides a web interface with a dashboard showing all relevant information (Figure 10). This is a
read-only page. No sensitive information is displayed. The page can be accessed by pointing a web browser
to the IP address of the clock. The only requirement is that the browser supports HTML5 and Java script.
If desired, access to this page can be password-protected as described in sections Access Passwords
(Online) and Access Passwords (Offline).
The information in the fields Identifier, Location, and Contact is set in General Settings (Online) or
in General Settings (Offline).
Description
Satellite is used for time calculation. The size of the circle indicates the signal strength.
Satellite is tracked but not used for time calculation.
Satellite is being acquired..
Table 2: Satellite visualization

Table of Contents