— 5-15 —
l The brake signal must be controlled through the user's sequence.
Figure 5-15 : Recommended sequence diagram
Close
Open
α
ON
ON
ON
A case to increase holding rigidity.
Close
Clamp
α
Servo on
Servo off
BRK output
Clamp
Close
Open
ON
OFF
A case for safrty brake.
α
α
α
ON
OFF
Servo state of
Motor
RUN input
Motor rotation
IPOS output
≠
IPOS output
(FW=0)
User side
brake signal
Brake state
IOFF input
Brake state
User side
brake signal
IOFF input
Table 5-16
Motor
type
Brake
model
Static friction torque
(N·m)
Torsional rigidity
(sec./N·m)
Brake engaging time
(msec)
Brake releasing time
(msec)
Capacity
(W)
YS2020 RNB2K 20 4.5 26 10 17
YS3040 RNB4K 40 4.9 62 3 23
YS4080 RNB8K 80 1.3 66 5 30
YS5120 RNB12K 120 1.9 78 9 33