Oki Data CONFIDENTIAL
43627911TH Rev. 3
189 /
Table 7-1-1 Operator Alarm (10/10)
Display Cause Error Description and Analysis
Judgement
Remedy 600 1200
Power Off/on
932: Error
Inverter CPU
Clock Frequency Error
The inverter CPU clock frequency
is not correct.
Does the error still occur? Yes
Check the connection of the
V72-3 board.
Replace the V72-3 board.
Power Off/on
933: Error
Trya2 CPU Clock
Frequency Error
The tray-2 CPU clock frequency is
not correct.
Does the error still occur? Yes
Check the connection of the
V72-1 board of tray 2.
Replace the V72-1 board.
Power Off/on
934: Error
Trya3 CPU Clock
Frequency Error
The tray-3 CPU clock frequency is
not correct.
Does the error still occur? Yes
Check the connection of the
V72-1 board of tray 3.
Replace the V72-1 board.
Power Off/on
935: Error
Trya4 CPU Clock
Frequency Error
The tray-4 CPU clock frequency is
not correct.
Does the error still occur? Yes
Check the connection of the
V72-1 board of tray 4.
Replace the V72-1 board.
Power Off/on
936: Error
Trya5 CPU Clock
Frequency Error
The tray-5 CPU clock frequency is
not correct.
Does the error still occur? Yes
Check the connection of the
V72-1 board of tray 5.
Replace the V72-1 board.
Power Off/on
940: Error
Waste Toner
Transfer Error
The transfer mechanism of the
toner duct for ID is not operating
properly.
Does the error still occur?
Yes
Yes
Yes
Check to confirm that the basket
assembly is in position (if it is
engaged with the gear of the
printer).
Check to confirm that the holder
magnet D contains a magnet,
and check the magnetic polarity.
Replace the HAL IC circuit
board.
Replace the duct assembly
toner.
Software not
authorized
001
Keychip check failed AS3 PCB KeyChip unmounted or
KeyChip Error is detected.
Power OFF/ON
Replace KeyChip
Software not
authorized
002
Unauthorized hard disk
copy
The AS3 PCB HDD is not a
standard (official) product.
Power OFF/ON
Replace HDD
Software not
authorized
003
Unauthorized software
configuration
The AS3 PCB HDD program does
not match the destination.
Power OFF/ON
Replace HDD
Software not
authorized
004
EEPROM missing The AS3 PCB EEPROM
unmounted or EEPROM Error is
detected.
Power OFF/ON
Replace EEPROM