2. TROUBLESHOOTING PROCEDURES
No. Category PJL Status
Code
Panel messages Description
97 Error - Please check data.
Program Data
Write Error
<%DLCODE%>
Indicates that an error has happened while writing
the SIP download data.
%DLCODE%
1: Data transfer error
2: No device space
3: Check sum error
4: Chip detection error
5: Chip erace error
6: Chip writing error
7: Chip verify error
8: Data error (Product code is wrong e.t.c.)
9: Data size error
98 Error 40712 Inspection is
required.
%ERRCODE%:
SIP Error
Indicates that the processing of Scan Image
Processing contller was failed.
User must turn Off/ On the power supply, if this
status occurred.
%ERRCODE%
4 digit hex code
99 Error 40724 Please call service.
Scanner unit failed
to detect printer
unit.
Indicates that scanner and printer is not
connected.
This message is displayed, if the communication
between scanner and printer units could not be
started.
User must turn Off/ On the power supply, if this
status occurred.
100 Error
(ONLINE)
40714 SIP Firmware
Missing
Indicates that the firmware in board can not be
detected.
101 Fatal
070
073
075
40057 Power OFF/ON
%ERRCODE%:Error
%FATALSTRING1%
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
'%FATALSTRING1%' specifies error code that is
the detailed error cause.
The message of fatal error is specified by English
only.
102 Fatal
203
204
40057 %ERRCODE%:Error
%FATALSTRING2%
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
'%FATALSTRING2%' specifies error code that is
the detailed error cause.
The message of fatal error is specified by English
only.
No. Category PJL Status
Code
Panel messages Description
103 Fatal
072
057
058
231
40057 Power OFF/ON
%ERRCODE%:Error
%CODE%
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
'%CODE%' specifies error code that is the
detailed error cause.
The message of fatal error is specified by English
only.
104 Fatal
209
40057
Power OFF/ON
%ERRCODE%:Download
Error
Downloading Media Table to PU has failed.
(Related to CustomMediaType.)
%ERRCODE%: specifies 3 digits (decimal) error
code.
The message of fatal error is specifiedby English
only.
"Download Error" is specified by Japanease and
English only.
105 Error 30938 A decoding error
occurred.
Check the image
data.
Indicates that an error has occurred during
analysis of image data input to the MFP from an
external source.
This appears when an error has occurred during
analysis of TIFF or JPEG data in A05:DirectPrint,
A07: InternetFAX, E-mailPrint, or FaxToPrint
(saving sent/received data) mode.
106 Error 30930 Process has been
cancelled as
spooler is full.
Please free up
memory space by
reducing use and
try again.
107 Error 30932 Process has been
cancelled by a
spooler device
error.
Please contact
administrator.
108 Error - Access denied to
PC.
Please check PC.
Indicates that PC rejects a PushScan request.
Select Close with the cursor and press [OK]
button, and the display will return to ScanTo
standby screen.
(At present, screens to return to after errors have
been reset vary from function to function.
It is desirable to return to the same screen.)