5238-E P-282
SECTION 12 USER TASK
Program example 3:
LE33013R0301400230005
After the execution of the program above, an alarm with a comment can be generated in N103.
LE33013R0301400230006
Program example 4:
LE33013R0301400230007
LE33013R0301400230008
Arithmetic variable
LE33013R0301400240001
NOEX command
Designated at the beginning of a variable setting sequence to speed up the "program check" by
eliminating single-block processing. (The operation is the same whether this command is
designated or not.)
The NOEX command is effective only in the single block mode operation with "1" set at NOEX
command ignore of optional parameter (OTHER FUNCTION 1).
N101
N102
N103
:
VUACM [1] = ' -L ^ K]'
VUACM [5] = ' = GEAR'
VDOUT [992] = 1000
........
corresponds to PART
........
=GEAR
Screen display 2288 Alarm B User reserve code 2000 ABCD
PART = GEAR
N301
N302
VUACM[1] = $41424344
VDOUT[992] = 2000
.
.......
Corresponds to ABCD
Screen display 2288 Alarm B User reserve code 2000 ABCD
VPAI
........
π (Ratio of circumference of circle to its diameter)

Table of Contents