SECTION 13 SCHEDULE PROGRAMS
2. PSELECT Block
[Function]
A PSELECT block selects and executes main programs for a workpiece to be machined.
This function searches a specified main program file for a specified main program to be
selected as a machining program. The function also searches a specified subprogram file, or
system subprogram file, and manufacturer subprogram file for the required subprograms and
selects them automatically.
It repeats selected programs as specified.
[Programming format]
The commands must be specified in the following order:
Commands enclosed by [ ] may be omitted. Note that a comma "," may also be omitted if the items
that follow are all omitted.
LE33013R0301500020001
fm: Main program file name
LE33013R0301500020002
If a device name, a file name, and/or an extension is omitted, entries of "MD1", "A", and "MIN",
respectively, are assumed to apply. If all entries for "fm" are omitted, "MD1:A.MIN" is assumed
to apply.
An alarm will occur if "*" or "?" is used in a main program file name.
An alarm will occur if the specified file does not exist.
pm: Main program name
LE33013R0301500020003
If entry of "pm" is omitted, the program name of the first program in the specified main program
file is assumed to apply.
An alarm will occur if the specified program does not exist in the selected main program file, fm.
An alarm will occur if M02 or M30, indicating the end of the program, is not specified in the
specified main program.
{PSELECT} [fm],[pm],[fs],[n](CR) or (LF)
Entries enclosed by [ ] may be omitted.
[ :] [ ] [. ]
3 characters
Within 16 characters 3 characters
Device name
File name
Extension
Within 5 characters
0