5238-E P-328
SECTION 14 OTHER FUNCTIONS
5-3-2. Parameters
The following parameters are added to allow the settings of amplitude (Q), cycle (P), and interval
timer (R).
(1) Spindle speed variation amplitude (Q)
Sets an amplitude of spindle speed variation.
(2) Spindle speed variation cycle (P)
Sets a cycle of spindle speed variation.
(3) Interval timer (R)
Sets an interval timer.
5-3-3. System Variables
The following system variables are added to allow the reading and writing of the above parameter
data.
Parameter word No.114
Setup unit 1[%]
Setup range 0 to 100
Default value 0
Parameter word No.115
Setup unit 0.1[sec]
Setup range 0 to 255
Default value 0
Parameter word No.116
Setup unit 0.1[sec]
Setup range 0 to 125
Default value 0
VFLTQ: Spindle speed variation amplitude (Q)
VFLTP: Spindle speed variation cycle (P)
VFLTR: Interval timer (R)