No.20S062-00
10/55
STC-LBGP251BCXP124 / STC-LCGP251BCXP124 / STC-LBGP251BCXP124-T / STC-LCGP251BCXP-T
Product Specifications and User’s Guide
Precautions
(*1) When Image Format is changed, ADC bits width also changes.
The ADC bits width cannot be changed.
Image Format ADC bits width
Mono8 / BayerRG8
->
10bits
Mono10 / BayerRG10
->
10bits
(*2) The pixel format (Bayer pattern) for color model is changed when image is flipping with image flip function.
The Bayer pattern in this document is Bayer pattern of image flip function Off.
(*3) The sensitivity is measuring the luminance when white level achieved 100 % in below conditions.
Camera Setting Environment
Parameter Setting Parameter Setting
Gain Up Factory Setting
Light Source Light Box (White)
AGC Off Color temperature
5,100K
White Balance Optimum Lens
Electrical Shutter
1/30 seconds F on Lens F5.6
Black Level Optimum Target Luminance
IM-600 (Topcon)
Gamma Factory Setting