10.2.2 User Output
High or low level signal that was configured on software is output.
Setting Procedure
Selects LineN (N: any number from 0, 1 or 2)
1) Sets the UserOutputN (N is Line number) as LineSource
2) Selects UserOutputN (N is same as selected Line number on UserOutput) on UserOutputSelector
3) Sets the value (True: High level, False: Low level) on UserOutputValue
10.2.3 LineStatus
Monitor the status on output port.
Monitor the output voltage level High (LineStatus: true) or Low (LineStatus: false) through software.
10.2.4 Output signal duration setting and Pulse width setting
Some selectable functions can be modified in order to add to duration or pulse width on Line Source.
The configurable parameters are shown in chart below.
Please refer to LineSource for applicable functions of parameters.
GenICam Parameters
TriggerOutDelay IInteger Type Trigger Out Delay Time
Range: 0 to 262,143 μseconds, Default: 0 μsecond
TriggerOutOnTime IInteger Type Trigger Out On Time
Range: 4 to 262,143 μseconds, Default: 32 μseconds
StrobeOutDelay IInteger Type Strobe Out Delay Time
Range: 0 to 262,143 μseconds, Default: 30 μseconds
StrobeOutOnTime IInteger Type Strobe Out On Time
Range: 4 to 262,143 μseconds, Default: 32 μseconds