No.20S062-00
28/55
STC-LBGP251BCXP124 / STC-LCGP251BCXP124 / STC-LBGP251BCXP124-T / STC-LCGP251BCXP-T
Product Specifications and User’s Guide
9.6 Trigger
These parameters set operational mode (trigger mode) and trigger type.
The selectable trigger types are listed in below table
GenICam Parameters
TriggerSelector IEnumeration Type Trigger function selection
Frame Start: Normal trigger function (Default)
Frame Burst Start: Burst trigger function
TriggerMode IEnumeration Type Operational mode (trigger mode) selection
Off: Free run operation (Default)
On: Trigger operation
TriggerSource IEnumeration Type Trigger type selection
* Please refers below table for details of trigger type
TriggerOverlap IEnumeration Type Trigger Overlap function selection
Off: Trigger overlap function is disabled (Default)
ReadOut: Trigger overlap function is enabled
Acquisition
BurstFrameCount
IInteger Type Frame Burst Start
Sets the number of frames that acquiring with trigger.
Range: 1 to 16,777,216
Default: 1
<TriggerSource selection>
Software Software trigger signal that generates by TriggerSoftware (Default)
Line0 External hardware trigger through Line0
Line1 External hardware trigger through Line1
Line2 External hardware trigger through Line2
Line3 External hardware trigger through Line3
LinkTrigger0 CXP trigger packet trigger
9.7 Image Flip
Flip the image through ReverseX and ReverseY.
GenICam Parameters
ReverseX IBoolean Type Switch ON / OFF at Horizontal
False: Horizontal Flip Off, True: Horizontal Flip On. Default: False
ReverseY IBoolean Type Switch ON / OFF at Vertical
False: Vertical Flip Off, True: Vertical Flip On. Default: False