9.19.2 Loading Camera Settings
Setting Procedure
1. Select “UserSetX” (or Default) at “UserSetSelector”
2. Execute “UserSetLoad”
9.19.3 Loading Camera Settings when the Camera Power is on
Setting Procedure
1. Set “UserSetX” or “Default” at “UserSetDefault”
9.19.4 Camera Settings Initialization
Please follow the below procedure for camera settings put back to factory default settings.
Setting Procedure
1. Selects “Default” at “UserSetSelector”.
2. Executes “UserSetLoad”.
3. Selects “UserSetX” at “UserSetSelector”
4. Execute “UserSetSave”
When UserSetLoad is executing,
the camera settings load from selected ROM
that was selected at “UserSetSelector” to
register at RAM.
When the camera power is on,
the camera settings load from selected ROM
that was selected at “UserSetDefault” to
register at RAM.