No.20S062-00
24/55
STC-LBGP251BCXP124 / STC-LCGP251BCXP124 / STC-LBGP251BCXP124-T / STC-LCGP251BCXP-T
Product Specifications and User’s Guide
8.5 The interval of trigger input
The minimum interval of trigger input is changed based on trigger overlap setting (TriggerOverlap).
The trigger input that does not match minimum interval condition, is invalid.
Please refer “Frame rate” section for “Number of sensor frame line” and “1 H time” in this section.
The minimum interval of trigger input is possible to check with “Frame Trigger Wait” signal through IO port.
When “Frame Trigger Wait” signal is Low status, input trigger signal is invalid.
8.5.1 The interval of trigger input when trigger overlap is disabling
The minimum interval of trigger input when trigger overlap is disabling:
Minimum interval [usec.] = Greater one of below two:
(a) Exposure time [usec.] + (19 x 1 H time [usec.])
(b) (([Number of lines of sensor frame] + 35) x 1 H time [usec.])
Minimum interval
Input trigger signal
(Edge preset, positive)
Exposure time
Sensor image out
Input trigger signal
(Pulse width, positive)