Product Specifications and User’s Guide
8.2 Edge Preset Trigger Mode
In this trigger mode with positive polarity, the expose starts at rising edge of trigger signal.
The exposure duration time is based on preset exposure setting stored by camera setting communication.
In this trigger mode with negative polarity, the expose starts at falling edge of trigger signal.
The exposure duration time is based on preset exposure setting stored by camera setting communication.
Expose
Image out
Trigger signal
(Positive polarity)
8.3 Pulse width trigger mode
In this trigger mode with positive polarity, the expose starts at rising edge of trigger signal and stops at falling edge
of trigger signal. The expose period is high states of trigger signal.
In this trigger mode with negative polarity, the expose starts at falling edge of trigger signal and stops at rising
edge of trigger signal. The expose period is low states of trigger signal.
Expose
Image out
Trigger signal
(Positive polarity)