No.20S062-00
25/55
STC-LBGP251BCXP124 / STC-LCGP251BCXP124 / STC-LBGP251BCXP124-T / STC-LCGP251BCXP-T
Product Specifications and User’s Guide
8.6 Burst trigger
When selecting the burst trigger (Frame Burst Start) operation, number of images acquiring by one trigger signal
with minimum acquisition interval. The number of acquisition images can be set at AcquisitionBurstFrameCount.
The another trigger signal input while acquiring images with burst trigger, is invalid.
Minimum interval
Trigger signal in camera
(Edge preset, positive)
Exposure time
Sensor image out
Trigger signal in camera
(Pulse width, positive)
Input trigger signal
(Edge preset, positive)
Input trigger signal
(Pulse width, positive)
Acquisition Burst Frame Count
Invalid