No.20S062-00
13/55
STC-LBGP251BCXP124 / STC-LCGP251BCXP124 / STC-LBGP251BCXP124-T / STC-LCGP251BCXP-T
Product Specifications and User’s Guide
5.4 Environmental Specifications
(*1) Please insure the camera is installed with appropriate heat dissipation to keep camera housing temperature
(top plate) is less than +60 deg. C when camera using ambient temperature is exceeded +37 deg. C.
If the camera has a mounted lens and a tripod with an aluminum plate, this could decrease camera housing
temperature for heat dissipation.
When the internal temperature sensor (Device Temperature Selector = Sensor) on the camera shows less than
+65 deg. C, the camera housing temperature (top plate) will be less than +60 deg. C.
Upper side of camera
STC-LxGP251BCXP124 STC-LxGP251BCXP124-T
Model Number STC-LBGP251BCXP124
STC-LBGP251BCXP124-T
Operational
Temperature /
Humidity
Minimum Environmental Temperature: 0 deg. C,
Environmental Humidity: 20 to 85 %RH (No Condensation)
Maximum Environmental Temperature: +37 deg. C or
Camera housing temperature (top plate) shall not exceed +60 deg. C (*1)
Environmental Humidity: 20 to 85 %RH (No Condensation)
Storage Temperature /
Humidity
Environmental Temperature: -20 to +75 deg. C,
Environmental Humidity: 20 to 85%RH (No Condensation)
Vibration 20 Hz to 200 Hz to 20 Hz (5 min. / cycle), acceleration 10G, XYZ 3 directions 30 min. each
Shock Acceleration 38 G, half amplitude 6 mseconds, XYZ 3 directions 3 times each
Standard Compliancy EMS: EN61000-6-2:2005, EMI: EN61000-6-4:2007+A1:2011
RoHS RoHS Compliance
Measuring point