6 I/O Interface
6 - 28
Vision System FH/FZ5 series Hardware Setup Manual (Z366)
[Output]
Applicable signals:
BUSY0, RUN/BUSY1, OR0 to 1, GATE0 to 1, ERROR,
DO0 to 15, READY0 to 1
[Output]
Applicable signals:
STGOUT0 to 3
When STGOUT0 to 3 are used, connect the COMIN terminal.
Item Specifications
Internal circuit diagram
Item Specifications
Internal circuit diagram
+
Each output terminal
COM OUT
Load
+
Each output
terminal
COM IN
COM OUT
Load
FZ5-600 Series/
FZ5-1100 Series:
COM OUT
COM IN
+
Each output
terminal
Load
FZ5-800 Series/
FZ5-1200 Series: