PUMA T2
Technical Handbook
General information
P/N: 779-0306/01
Revision 03
OTE Proprietary information
Page 21
Tab. 1.2: Technical characteristics (Cont’d)
Environmental characteristics
Operating temperature –25° to +55 °C (ETS 300 019-2-7)
Storage temperature
–40° to +65 °C (ETS 300 019 sec. 1-1 class 1-2)
Relative humidity
95% at 40 °C non condensing
Conformance with environmental standard
Cold conformance ETS 300 019-2-7 class 7.3 E
Dry hot conformance ETS 300 019-2-7 class 7.3 E
Thermal cycles conformance ETS 300 019-2-7 class 7.3 E
Vibrations conformance ETS 300 019-2-7 class 7M3
Shock conformance ETS 300 019-2-7 class 7M3
Rain and dust conformance IP 54
Transmitter characteristics
Modulation
π/4 DQPSK
Maximum power in antenna
1W
Power of undesired output in non
active transmission state
in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Adjacent channel power due to
modulation
in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Adjacent channel power due to
commutation transistors
in compliance with EN 300 392-2 for Trunked Mode;
in compliance with EN 300 396-2 for Direct Mode
Undesired emissions far from the
carrier
in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Receiver characteristics
Sensitivity in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Rejection of co-channel in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Rejection of adjacent channel in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Blocking characteristic in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Rejection of spurious responses in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Rejection of inter-modulation
response
in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode;
Conducted emission undesired in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode
Irradiated emission undesired in compliance with EN 300 392-2 for Trunked Mode;
in compliance with ETS 300 396-2 for Direct Mode