PUMA T2
Technical Handbook
General information
Page 20 OTE Proprietary information
P/N: 779-0306/01
Revision 03
1.11 TECHNICAL CHARACTERISTICS
The technical characteristics of the equipment are shown in Tab. 1.2.
Tab. 1.2: Technical characteristics
Parameter Value
Dimensions
Hand-portable (including standard
battery and rotary knobs and
excluding the antenna)
159x65x45 mm
Weight
Hand-portable (without battery
pack)
315 g
Electrical characteristics
Air interface signalling EN 300-392-2; ETS 300 396-2
Power class 1 W
Frequency band (Trunked mode)
T2-400: 380÷400 MHz
T2-430: 410÷430 MHz
T2-470: 450÷470 MHz
T2-870: TX 806÷825 MHz; 851÷870 MHz
Frequency band (Direct mode) T2-400: 380÷400 MHz
T2-430: 410÷430 MHz
T2-470: 445.2÷445.3 MHz, 450÷470 MHz
T2-870: 851÷870 MHz
Automatic power control Open Loop and Closed Loop with step of 5dBm
from 15dBm to 30dBm, according to EN 300 392-2
Carrier spacing 25 kHz
Receiver class EN 300 392-2 class A and class B
RF architecture Half-duplex
Audio power
500 mW, 25 Ω
Power source NiMH 1800 mAh; Li-ion 2700 mAh;
NiCd 1600 mAh
Nominal supply voltage 7.2/7.4 Vdc
Power consumption (average on
frame, single timeslot)
Stand by: 100 mA
Receiving mode: 150 mA
Transmitting mode: 430 mA
EMC specifications EN 301 489-18
SAR In compliance with CENELEC EN 50360 and with
the European Council recommendation
1999/519/CE