Executing the force cancel (Programs and security information are all deleted.)
Click [Force cancel].
Click [Yes].
If the current status is Password is not set, this
procedure has completed.
All programs and security information were
deleted.
About the password data of the master memory cassette (AFPX-MRTC)
The data on the password setting can be transferred to the master memory cassette together with the
programs from the FP-X.
The password information stored in the master memory cassette will be automatically transferred to
another control unit when it is installed, and the control unit will be protected.
The procedure of the transfer to the master memory is as below.
1. Turn off the power supply of the PLC, and set the RUN/PROG mode switch to the PROG mode. Install
the master memory cassette to transfer the program on the control unit.
2. 2. Turn on the power supply of the PLC, and transfer the program to the master memory cassette
using Internal memory => Master memoryin the programming tool.
Reference:
For the information on the transmission to the master memory cassette,
<12.2.2 Master Memory Function>