669
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
U12 Staple Door / Top Door open 1) Is the stapler door or top door closed correctly?
2) Stapler door or top door open/close sensor
connector is shorted or broken.
3) Stapler door or top door open close sensor is
defective.
4) Finisher CPU PCB connector is shorted or
broken.
5) Finisher CPU PCB is defective.
6) LVPS connector is shorted or broken.
7) LVPS is defective.
8) CPU PCB connector (CN15) is shorted or broken.
9) CPU PCB is defective.
U30 Finisher Punch Cover open 1) Is the punch cover closed correctly?
2) Punch cover open/close sensor connector is
shorted or broken.
3) Punch cover open/close sensor is defective.
4) Punch unit CPU PCB connector is shorted or
broken.
5) Punch unit CPU PCB is defective.
6) Finisher CPU PCB connector is shorted or
broken.
7) Finisher CPU PCB is defective.
8) LVPS connector is shorted or broken.
9) LVPS is defective.
10) CPU PCB connector (CN15) is shorted or broken.
11) CPU PCB is defective.
U31 Finisher Saddle Unit paper removal 1) Copy paper is already in finisher saddle unit.
2) Copy paper which is unsuitable size is in saddle
unit.
3) Too many copy paper in saddle unit.
4) Finisher saddle unit paper detecting sensor
connector is shorted or broken.
5) Finisher saddle unit paper detecting sensor is
defective.
6) Finisher CPU PCB connector is shorted or
broken.
7) Finisher CPU PCB is defective.
8) LVPS connector is shorted or broken.
9) LVPS is defective.
10) CPU PCB connector (CN15) is shorted or broken.
U32 Finisher Saddle Unit Feed Cover open 1) Is the saddle unit feed cover closed correctly?
2) Saddle unit feed cover open / close sensor
connector is shorted or broken.
3) Saddle unit feed cover open / close sensor is
defective.
4) Saddle unit CPU PCB connector is shorted or
broken.
5) Saddle unit CPU PCB is defective.
6) Finisher CPU PCB connector is shorted or
broken.
7) Finisher CPU PCB is defective.
8) LVPS connector is shorted or broken.
9) LVPS is defective.
10) CPU PCB connector (CN15) is shorted or broken.
11) CPU PCB is defective.