147
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
6. If the gap is less than 5 mm, input a (+) value. If more than 5 mm, input a (-) value.
7. Press "STOP" key first and then press "FUNCTION" + "CLEAR" keys simultaneously to return to
standby.
3.9. QUANTUM Control in F8-14
To stabilize the initial print quality, the contents of the F8-14 function was changed beginning from June '02
production. (Starting with Serial No. FBG2Kxxxxxx)
1. Description of the Change
2. Field Installation Procedure
* For New machines, use the followin
procedures at installation.
* For Machines alread
set up, use the followin
procedures during PM
1. Make sure that the LAN cable is disconnected before performing F8-09
2. Make sure that paper is set in an
paper tra
before performing F8-09
3. After performing F8-14, please use the additional procedure manuall
for all machines
which were produced from Feb ’02 to Ma
’02 production.
(Serial No. range from BBG2Kxxxxxx to EBG2Kxxxxxx).
3. QUANTUM Control Timin
Refer to the following Table.
Toner Density Sensor
Output Gain Adj.
Self-Adjusting
(QUANTUM) 1min
Ready
Go to Image
Quality Adj.
F8-14 Contents
Toner Density Sensor
Output Gain Adj.
Ready
Go to Image
Quality Adj.
F8-14 Contents
Current
New
Proceed to
F8-14
Turn Power
Switch OFF/ON
Ready
Wait approx.
90 sec.
Ready
Self-Adjusting
(QUANTUM) 1 min
Ready
Go to Image
Quality Adj.
Additional Procedure