4.6. Information Codes Table (For Facsimile)
Fax Information Codes
Code Mode Phase Description of Problem Cause
012 RCV C, D The length of the received
document is over 2 m.
Transmitter Document Jam.
030 XMT B Read Point Sensor does not
activate within 10 seconds after
the document starts feeding.
Document is not set properly.
Defective Read Point Sensor.
031 XMT
COPY
C Transmitting document was longer
than 2,000 mm (or 78.7 in).
(Super Fine: 1,000 mm (or 39.4
in), 600 dpi: 430 mm (or 16.2 in))
The document may jam.
Defective Read Point Sensor.
061 - A ADF Door is open. Cover is not firmly closed.
Connectors are not firmly connected.
200 RCV C Decoding process is not
completed at the end of phase C.
Defective FXB PCB.
212 XMT
RCV
A-E Interface error occurred between
the CPU and modem.
Modem is defective. (FXB PCB)
Software problem occurred. (SC PCB)
301 XMT
RCV
System fault. Software problem occurred. (SC PCB)
331 XMT C 8-minutes timer error.
(Germany only)
400 XMT B T1 timer (35±5 sec) elapsed
without detecting 300 bps signal.
Wrong number is dialed and the START
button is pushed.
Telephone line is disconnected while
dialing.
FXB PCB (Modem) or MJR PCB is
defective.
Receiver is defective. (It may only be
transmitting CED)
401 XMT B DCN was returned from receiver
while transmitter is waiting for CFR
or FTT.
Your machine's ID Number is not
programmed.
Possible incompatibility or incorrect
Password (Password Reception,
Selective Receive).
Mailbox is full.
402 XMT B DCN was returned from receiver
while transmitter is waiting for
NSF/DIS.
Receiver working in non-CCITT mode
only. (Possible incompatibility)
403 RCV
(Polling)
B Transmitter had no polling
function.
"POLLED=ON" (polling XMT ready) is
not set at the transmitter.
Document to be transmitted is not
placed at the transmitter.
404 XMT B Transmitter sent NSS (or DCS)
followed by TCF three times, but
the receiver did not respond. (CFR
or FTT is usually returned)
Receiver is defective. (Modem, MJR
PCB, etc.)
FXB PCB or MJR PCB is defective.
Receiver disconnects line during first
NSS (or DCS) is transmitted.