800
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
11.3.4. Maintenance and Inspection
11.3.4.1. Periodically Replaced Parts
11.3.4.1.1. Finisher / Saddle Unit
The unit does not have components that require periodical replacement.
11.3.4.1.2. Punch Unit (Option)
The unit does not have components that require periodical replacement.
11.3.4.2. Consumables and Durables
Some components of the Machine may require replacement once or more over the period of machine
warranty because of deterioration or damage. Replace them as needed.
11.3.4.2.1. Saddle / Finisher Unit
Table. 4-001
11.3.4.3. Scheduled Maintenance
Table. 4-002
No. Part Name Part No. Q’ty Expected Life Remarks
1 Stapler 4G1-4268-000 1 300,000 operations
A single cartridge is
good for about 5,000
operations.
Item Interval Description Remarks
Feeding Assembly Roller
Minimum maintenance intervals
of host machine
Cleaning
Wiping with water.Feeding Assembly Member
Paper Path Guide
Transmission Type Sensor
(Optional Punch Unit)
Dry wiping.