4-2-2 Command Formats
The following section explains seven types of command formats transmitted
from an external host device to the HL-G1.
FORMAT
ᵏᴾ
General Purpose
The following command formats are used to read or make general
measurement mode settings or operating conditions.
Ɣ Read Command
Read command formats are used to read operating conditions.
Request communication data
Normal response data
Reading the sampling cycle setting value for sensor 01 in the RS-422
handshake mode or the RS-485 multi-mode
Request communication data
Normal response data
Ex
ᴾ
% $ R
s
Sender no. Command
BCC
CR
0 1 2 3 4
Data block: 1
-character symbol +
5
-character integral part (no zero suppress)
BCC
% # R
CR
Destination no. Command
% 0 1 $ R S P
+
CR
㻖
㻌
㻖㻌
0 0 0 0 1
Sampling
cycle:
>ȝV@
% 0 1 # R S P
CR
**
Ramco Innovations
800
280-6933 www.panasonicsensors.com nsales