Alarm Delay Times
This function holds the previous normal value up to the setting number of
times if an alarm is issued.
The previous normal value will be kept on hold up to the setting number of delay times
if an alarm is issued (where measurement is disabled owing to lack of light).
㻌
Alarm output (OUT3) will be turned ON when the alarm status continues more than
the setting number of delay times, and analog output and digital output will be turned
ON according to the setting for analog output at alarm and the setting for digital
output at alarm, respectively.
㻌
㻌
㻌
This function is effective if the user does not require the output o
instantaneous alarms resulting for the surface condition changes o
measurement objects.
㻌
㻌
Setting range Function Initial value
0 to 65534
0 (OFF) to 65534 times
㻌
㻌
65535
Holds the measurement value
before the alarm.
㻌
Ɣ6HWWLQJ3rocedure
1
Display the "Alarm Setting" screen while
in setting mode.
㻌
2
3UHVVWKH>(17(5@NH\7KH$QDORJ
output at alarm" screen will be displayed.
㻌
3
3UHVVWKH>'2:1@NH\WZLFH7KH$ODUP
Delay Times" screen will be displayed.
㻌
4
Press the [ENTE5@NH\7KHQXPEHURI
alarm delay times will be displayed. The
leftmost digit will be selected.
㻌
5
3UHVVWKH>83@>'2:1@NH\VWRJHWKHUWR
change the selected digit.
㻌
6
3UHVVWKH>83@>'2:1@NH\WRFKDQJHWKH
value of the selected digit. (Example:
Changing the value to 0 times (OFF).)
㻌
7
3UHVVWKH>(17(5@NH\DQGGHWHUPLQHWKH
number of delay times.