Data Buffering Operation㻌
Data buffering procedure
1
0DNHQHFHVVDU\VHWWLQJVIRU
buffering.
Buffering mode
㻌
Buffering rate
㻌
Accumulation amount
Trigger conditions
㻌
Trigger delay
㻌
Trigger point
2
Transmit the start command and start
buffering.
Buffering operation start
㻌
3
Start data accumulation.
Start accumulation to the built-in
memory of the sensor head.
㻌
* The start of accumulation varies
with each buffering mode.
㻌
4
Wait until accumulation is completed.
The accumulation status can be
checked by "Status Readout."
㻌
Status Readout
㻌
㻌
5
Stop buffering by transmitting the
stop command.
Buffering operation stop
㻌
㻌
6
Read out the accumulated data result.
Last data point
㻌
Data readout (normal)
㻌㻌
Data readout (high speed)
㻌
㻌
㻌
No settings related to buffering can be changed while the system is in buffering operation.
Change the settings after stopping the buffering operation of the system.
㻌
(1) Send settings
(2) Buffering start
6WDWXVFKHFN
(5) Buffering stop
(6) Accumulated
data readout
HL-G1 PC (Host device)
(3) Accumulation
start
Yes
No
Is accumulation
completed?
Ramco Innovations
800
280-6933 www.panasonicsensors.com nsales
ramcoi.com