EasyManua.ls Logo

Panasonic HL-G1 Series - Format; Timing

Panasonic HL-G1 Series
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Normal response data
* Binary data on each point of response data is in 4 bytes in order of the
lowest byte to highest byte. (Little endian)
Example)
Head point ĺ(Binary) 0x0012D687 = (Decimal) + 1234567
Second point ĺ%LQDU\0x0012D71F ĺ'HFLPDO+ 1234719
FORMAT
ᵕᴾ
RS-422 Timing (or RS-422 Continuous)
Output Mode
The following dedicated command formats are used to output data if “RS-422
timing” or “RS-422 continuous” is selected in "3-3-8 COM Setting" -
"Connection Mode".
Sensor transmission data
RS-422 Timing
The measured value data when the timing input is turned ON will be output
while the timing input is ON.
RS-422 Continuous
Measured value data is output repeatedly in the above format on and after
the RS-422 continuous output mode is selected.
% $
s
1 2 3
Sender no.
BCC
CR
㻖㻌
4 5 6 7
Data block: 1
-characte
r symbol
+ 7
-character integral part (no
zero suppress)
Sender no. Command
Binary data to
end point
D6
1F
Head point
binary data
Binary data to
end poi
nt
87
00 12
00
D7
12
% $ R L C
00
BCC
CR
12 D6 87
00 12 D7 1F
Ramco Innovations
(
800
)
280-6933 www.panasonicsensors.com nsales
@
ramcoi.com