Laser Control
This function is used to select the laser emission/stop.
This function makes it possible to stop unrequired laser emission while the system
is not in measurement operation.
Setting Function Panel display
Emission
Laser emission is ON
Stop
Laser emission is OFF
* indicates the default value.
The system will be in a data unficed state when the laser control is set to "Stop,"
and the data unstable state continues until "Emission" is set again.
The state returns to the measurement state when the laser is emitted again.
Ɣ6HWWLQJ3URFHGXUH
1
Display the "System Setting" screen
while the system is in setting mode.
2
3UHVVWKH>(17(5@NH\7KH7LPLQJ
Mode" screen will be displayed.
3
3UHVVWKH>'2:1@NH\RQFH7KH
"Laser Control" screen will be displayed.
4
Press WKH>(17(5@NH\7KH212))
will be displayed.
5
3UHVVWKH>83@>'2:1@NH\WRVHOHFW
ON/OFF. (Example: Changing the
selection to OFF.)
6
3UHVVWKH>(17(5@NH\WRGHWHUPLQH
the set value.