Measurement Value Display on Panel
The rightmost digits on the digital display can be turned OFF.
Setting Function Panel Display
FULL
All the digits are displayed.
Set 1
The rightmost digit is OFF.
Set 2
The rightmost two digits are OFF.
* indicates the default value.
Ɣ6HWWLQJ3URFHGXUH
1
Display the "Output Setting" screen
while the system is in setting mode.
2
3UHVVWKH>(17(5@NH\7KH-XGJPHQW
Output Selection" screen will be
displayed.
3
3UHVVWKH>'2:1@NH\ILYH times. The
"Measurement Value Display on Panel"
screen will be displayed.
4
3UHVVWKH>(17(5@NH\7KH
"Measurement Value Display on Panel"
screen will be displayed.
5
3UHVVWKH>83@>'2:1@NH\WRPDNHD
setting change for the measurement
value display on the panel. (Example:
Changing the present setting to Set 2.)
6
3UHVVWKH>(17(5@NH\WRGHWHUPLQHWKH
setting for the measurement value
display on the panel.
ƔSet2 usage example
In this example "FULL" is changed to "Set2."